Best selling Energy monitors from Eltako

On this page you'll find a ranking of the best Eltako products in this category. To give you a quick overview, we've already ranked the most important information about the products for you.

1. Eltako Three-phase meter

Eltako Mobile Three-Phase Meter DSZ180CEE-16

Manufacturer: Eltako
Description: Mobile Three-Phase Meter MID calibrated 16A
Type: DSZ180CEE-16
Meter Type:
electronic
Rated Current (In): 10 A
Maximum Current (Imax): 80 A
Rated Voltage (Un) N-L: 230 V
Rated Voltage (Un) L-L: 400 V
Frequency: 50 Hz
Accuracy Class: B
Polarity: Four-Wire
Design: Direct Measurement
Energy Type: Active Power
Suitable for: Consumption
Reverse Lock: yes
Calibrated: yes
Approval: Measuring Instruments Directive
Display Type: digital
Width: 86 mm
Depth: 82 mm
Height: 180 mm
Interface Design: other
Number of Digits: 7
Protection Class (IP): IP54

Additional Details: Mobile three-phase meter with CEE plug 16A and CEE socket 16A. Suitable for indoor and outdoor use. Maximum current 16A, standby loss only 0.5 watts per path. Housing dimensions 180x86x82 mm, connection cable 1.5 m (including plug and socket). Accuracy class B (1%). This mobile three-phase meter measures active energy based on the currents flowing between the inputs and outputs. The self-consumption of a maximum of only 0.5 watts of active power per path is not measured and not displayed. The starting current is 40 mA. The display can only be read with power supply. However, the consumption is stored non-volatile and is immediately displayed again after a power failure. The digital display has 7 digits. Up to 99999.99 kWh, two decimal places are displayed; from 100000.0 kWh, only one decimal place is shown. The power consumption is indicated by a bar that blinks 100 times per kWh on the display. EAN: 4010312501863.
 

2. Eltako DSZ15EN

Maximum current 3x80A, standby loss only 0.5 watts per path. Modular device for mounting on DIN rail EN 60715 TH35. 4 division units = 70 mm wide, 58 mm deep. Accuracy class B (1%). With S0 interface. The directly measuring three-phase energy meter measures active energy based on the currents flowing between the inputs and outputs. The self-consumption of only a maximum of 0.5 watts active power per path is not measured and not displayed. 1, 2, or 3 external conductors with currents up to 80A can be connected. The inrush current is 40 mA. The neutral connection must be present. The 7-segment LC display can also be read twice within two weeks without power supply. Power consumption is displayed with a bar that blinks 100 times per kWh. Standardly usable as a 2-tariff meter: by applying 230V to terminals E1/E2, it switches to a second tariff. To the right of the display are the MODE and SELECT buttons. 

3. Eltako Alternating current meter MID calibrated

Only calibrated meters are approved for electricity billing according to §25 of the German Calibration Act. Non-compliance is an administrative offense under §19. Maximum current is 65 A, with a standby loss of only 0.4 watts. This is a modular device for mounting on a DIN-EN 60715 TH35 rail. 1 modular unit = 18 mm wide, 58 mm deep. Accuracy class B (1%). Equipped with an S0 interface. This AC meter measures active energy based on the current flowing between the input and output. The self-consumption of only a maximum of 0.4 watts of active power is not measured and not displayed. One external conductor with a current of up to 65 A can be connected. The starting current is 40 mA. If a load exceeding 50% is expected, a ventilation distance of 1/2 modular unit must be maintained from adjacent devices. If necessary, use the spacer DS12. Two N terminals for secure cross-wiring of multiple meters. The 7-segment LC display can also be shown twice within two weeks without power supply. 

4. Eltako DSZ15DZ-3x80A MID

Maximum current 3x80A, standby loss only 0.5 watts per path. Modular device for mounting on DIN rail EN 60715 TH35. 4 division units = 70mm wide, 58mm deep. Accuracy class B (1%). With S0 interface. The directly measuring three-phase energy meter measures active energy based on the currents flowing between the inputs and outputs. The self-consumption of only a maximum of 0.5 watts active power per path is not measured and not displayed. The active energy is summed depending on the sign. Positive power in the meter indicates energy consumption, while negative power indicates energy delivery. Energy measurement is net. If energy consumption (P positive) is greater than energy delivery (P negative), the meter reading T arrow right increases. If energy delivery is greater than energy consumption, the meter reading T arrow left increases. Energy consumption is indicated with a right arrow and energy delivery with a left arrow above the active bar on the display. 1, 2, or 3 external conductors can be connected with currents up to 80A. The starting current is 40mA. The neutral connection must be present. The 7-segment LC display can also be read twice within two weeks without power supply. Power consumption is displayed with a bar blinking 100 times per kWh on the display. To navigate through the menu according to the user manual, there are MODE and SELECT buttons located to the right of the display. First, the background lighting turns on. Then, the total active energy for consumption and delivery, the active energy of the resettable memory for consumption and delivery, as well as the instantaneous values for power, voltage, and current per external conductor can be displayed. Error message (false): If an external conductor is missing, false is displayed along with the corresponding external conductor. 

5. Eltako AC meter reset uncalibrated

Maximum current 32A, standby loss only 0.5 watts. Modular device for mounting on DIN rail EN 60715 TH35. 1 module unit = 18 mm wide, 58 mm deep. This AC meter with reset function measures the active energy based on the current flowing between the input and output and stores the consumption in non-volatile memory. Like all meters without MID compliance declaration, it is not approved for monetary electricity billing in Europe. The accuracy is in line with all Eltako AC meters of class B according to MID (1%), with a starting current of 20 mA. The display is divided into 3 fields. Field 1: This display refers to the accumulated value in Field 3. Slowly moving to the right = Field 3 shows the consumption since the last reset. This is the normal display. S01 = Field 3 shows the consumption of the last full hour up to S24 = 24 hours ago. T01 = Field 3 shows the consumption of the last full days up to T95 = 95 days ago. Field 2: Current value. 

6. Eltako Alternating current meter

Only calibrated meters are approved for electricity billing according to §25 of the German Calibration Act. Non-compliance is an administrative offense under §19. Maximum current is 32A, with a standby loss of only 0.4 watts. This is a modular device for mounting on a DIN-EN 60715 TH35 rail. 1 division unit = 18mm wide, 58mm deep. Accuracy class B (1%). Equipped with an S0 interface. This alternating current meter measures active energy based on the current flowing between the input and output. The self-consumption of only a maximum of 0.4 watts of active power is not measured or displayed. One external conductor can be connected with a current of up to 32A. The starting current is 20mA. For expected loads exceeding 50%, a ventilation distance of 1/2 division unit must be maintained from adjacent devices. If necessary, use the spacer DS12. Two N terminals for safe cross-wiring of multiple meters. The 7-segment LC display can also be shown twice within two seconds without power supply. 

7. Eltako MBusWandlerThree-phase meter MID calibrated

Only calibrated meters are approved for electricity billing according to §25 of the German Calibration Act. Non-compliance is an administrative offense under §19. M-Bus converter three-phase meter with adjustable converter ratio and MID. Maximum current 3x5A, standby loss only 0.5 watts per path. Rail-mounted device for installation on DIN-EN 60715 TH35 mounting rail. 4 division units = 70 mm wide, 58 mm deep. Accuracy class B (1%). With M-Bus interface. This three-phase meter measures active energy based on the currents flowing through the converters. The self-consumption of only a maximum of 0.5 watts active power per path is not measured and not displayed. 1, 2, or 3 converters can be connected with secondary currents up to 5A. The starting current is 10 mA. The neutral connection must be present. The 7-segment LC display can also be read twice within two weeks without power supply. The power consumption is indicated by a LED that blinks 10 times per kWh. To the right of the display is... 

Eltako MBusWandlerThree-phase meter MID calibrated
Energy monitors
CHF207.30

Eltako MBusWandlerThree-phase meter MID calibrated

8. Eltako Air

The sensor is mounted with its attachment magnet above the IR output of the meter and connected via its connection cable to the terminals Tx, Rx, GND, and +12V of the RS485 bus power meter data gateway FSDG14. 

9. Eltako MOBILE A.C. Z. MID GEE (WSZ155DSS-16A)

Mobile AC power meter with protective contact plug and socket. Suitable for indoor and outdoor use. Maximum current 16 A. Protection class IP54. Standby loss of only 0.4 watts. Housing dimensions 155 x 60 x 82 mm, connection cable 1.5 m (including plug and socket). Accuracy class B (1%). This mobile AC power meter measures active energy based on the current flowing between the input and output. The self-consumption of only a maximum of 0.4 watts of active power is not measured or displayed. The display cyclically alternates every 10 seconds between the accumulated active energy in kWh and the current consumption in kW. The starting current is 20 mA. The display can only be read when powered. However, the consumption is non-volatile and will be immediately displayed again after a power failure. The digital display has 7 digits. Up to 99999.99 kWh, two decimal places are shown; from 100000.0 kWh, only one decimal place is displayed. The mobile AC power meter is equipped with a mounting bracket for easy installation, which can be easily removed if not needed. Power consumption is indicated by a LED that blinks 2000 times per kWh. 

10. Eltako DSZ15WD-3X5A MID

Only calibrated meters are approved for electricity billing according to §25 of the German Calibration Act. Non-compliance is considered an administrative offense under §19. This is a transformer three-phase meter with adjustable transformer ratio and MID. Maximum current is 3x5A, with a standby loss of only 0.5 watts per path. It is a modular device for mounting on a DIN-EN 60715 TH35 rail. It occupies 4 division units = 70mm wide, 58mm deep. Accuracy class B (1%). Equipped with an S0 interface. This three-phase meter measures active energy based on the currents flowing through the transformers. The self-consumption of only a maximum of 0.5 watts active power per path is not measured or displayed. It can connect 1, 2, or 3 transformers with secondary currents up to 5A. The starting current is 10mA. The neutral connection must be present. The 7-segment LC display can also be read twice within two weeks without power supply. The power consumption is indicated by a bar that blinks 10 times per kWh on the display.