Eaton RCD circuit breaker
8 pieces in stock at third-party supplier
Product details
Symmetrical distribution of the ballasts on all phases is advantageous. The function of the switch is independent of the position.- The circuit breaker can therefore be used for "fault protection" and "additional protection" in accordance with the installation regulations.- The 4-pole switch can also be used with 2 or 3 poles. See connection examples.- The test button "T" must be actuated every year The system operator must be demonstrably informed about this circumstance and his responsibility. When used under special conditions (construction sites, laboratories), the test button may have to be pressed more often. Here, the statements of the respective installer regulations apply.- By pressing the test button "T", only the function of the residual current device (RCD) is tested. This test does not replace the earth resistance measurement (RE), nor the proper protective conductor status test, which must be carried out separately.- Type- -/B: Short-time delayed + surge-proof 3 kA, all-current sensitive, type B (ÖVE E 8601)- Type- -/B: High reliability against false tripping. Mandatory for circuits with possible personal injury or property damage in case of false tripping (ÖVE/ÖNORM E 8001-1 § 12.1.6).- Type- -S/B: Selective + impulse-proof 5 kA, all-current sensitive, type S/B- Type- -S/B: Selective residual current circuit breaker. Protects with all types with residual current forms.
Circuit breaker type | Fault current circuit breaker |
Length | 80 mm |
Width | 70 mm |
number of poles | 4 |
Mounting type | Top-hat rail |
Item number | 14803223 |
Manufacturer | Eaton |
Category | Residual-current device |
Manufacturer no. | 300302 |
Release date | 20.2.2021 |
External links |
Colour | White |
Exact colour description | White |
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 4 |
Tripping characteristic | B |
Rated current | 63 A |
Rated current | 0.03 A |
Rated voltage | 400 V |
voltage type | AC |
Rated insulation voltage Ui | 440 V |
Residual current (rated differential current) | 0.03 A |
Protection type (IP code) | IP20 |
Country of origin | China |
Manufacturer commitment | SBTi |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 80 mm |
Width | 70 mm |
Height | 45 mm |
Length | 9 cm |
Width | 8 cm |
Height | 8 cm |
Weight | 250 g |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0.1 %
- 5.ABB0.2 %
- 5.Hager0.2 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- EatonNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- HagerNot enough data
- Schneider ElectricNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 3.Schneider Electric1.7 %
- 4.ABB1.9 %
- 5.Eaton3.3 %
- 6.Siemens3.8 %
- 7.Hager4.9 %