Symmetrical distribution of the control devices across all phases is advantageous. Follow the installation instructions provided by the control device manufacturer. The switch operates independently of its position. Therefore, the protective switch can be used in accordance with the installation regulations for fault protection and additional protection. The 4-pole switch can also be used as a 2- or 3-pole switch. See connection examples. The test button "T" should be pressed once a year. The plant operator must be informed in writing about this requirement and its responsibility. In special conditions (construction sites, laboratories), the test button may need to be pressed more frequently. The statements of the respective installation regulations apply here. Pressing the test button "T" only tests the function of the residual current (FI) protective switch. This test does not replace the measurement of earth resistance (RE) or the proper inspection of the protective conductor, which must be conducted separately. Type B: Short-time delayed and surge-resistant 3 kA, all-current sensitive, Type B (ÖVE E 8601). Type B: High reliability against false tripping. Mandatorily required for circuits with potential risk of personal injury or property damage in the event of false tripping (ÖVE/ÖNORM E 8001-1 § 12.1.6). Type S/B: Selective and surge-resistant 5 kA, all-current sensitive, Type S/B. Type S/B: Selective residual current protective switch. Protects against all types of residual current forms.
Circuit breaker type | Fault current circuit breaker |
Length | 80 mm |
Width | 70 mm |
number of poles | 4 |
Mounting type | Top-hat rail |
Item number | 14719865 |
Manufacturer | Eaton |
Category | Residual-current device |
Manufacturer no. | 300299 |
Release date | 2.2.2021 |
Colour | White |
Exact colour description | White |
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 4 |
Tripping characteristic | B |
Rated current | 40 A |
Rated current | 0.03 A |
Rated voltage | 400 V |
voltage type | AC |
Rated insulation voltage Ui | 440 V |
Residual current (rated differential current) | 0.03 A |
Protection type (IP code) | IP20 |
Country of origin | China |
Manufacturer commitment | SBTi |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 80 mm |
Width | 70 mm |
Height | 45 mm |
Weight | 320 g |
Length | 9 cm |
Width | 8 cm |
Height | 8 cm |
Weight | 420 g |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0.1 %
- 5.ABB0.2 %
- 5.Hager0.2 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- EatonNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- HagerNot enough data
- Schneider ElectricNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 3.Schneider Electric1.7 %
- 4.ABB1.9 %
- 5.Eaton3.3 %
- 6.Siemens3.6 %
- 7.Hager4.9 %