Best Schneider Electric products in the Residual-current device category
On this page you'll find a ranking of the best Schneider Electric products in this category. To give you a quick overview, we've already ranked the most important information about the products for you.
1. Schneider Electric Residual current circuit breaker
The residual current circuit breaker from Schneider Electric, model A9D56616, is a highly advanced device that functions both as a residual current device (RCD) and as a circuit breaker (MCB). With a rated current of 16 A and an earth fault sensitivity of 30 mA, this switch provides comprehensive protection for final circuits against overloads and earth faults. It is designed for use in alternating current applications with a rated voltage of 230 V and meets the requirements of the EN 61009 standard. The switch is suitable for mounting on a DIN rail and features a compact design that allows for easy installation. Its robust construction ensures high reliability and durability, while the IP20 protection rating makes it suitable for use in dry indoor environments. The A9D56616 is an essential component for the safety of electrical installations and offers an effective solution to prevent electrical accidents.
- Combination of residual current protection and overload protection
- Earth fault sensitivity of 30 mA for enhanced safety
- Robust design with IP20 protection rating
- Suitable for mounting on DIN rails
- Complies with the EN 61009 standard for safety and reliability.

2. Schneider Electric TeSys GV2ME motor circuit breaker 2.5-4A
Area: TeSys
Connection type: Screw mounting
Series: GV2M
UL and CSA certified motor protection switch - GV2-ME. Designed for use with TeSys controllers up to 15 kW. Provides short-circuit and overload protection and can be locked in the off position. Auxiliary contacts can be used to indicate a stop or a trip. Features screw terminals.

3. Schneider Electric Residual current circuit breaker
Rated current: 40 A. Tripping sensitivity: 30mA. Rated AC voltage: 400 V, 415 V. DIN rail mounting. Range: Acti 9. tripping time: instantaneous. Series: iID. Acti9 iID residual current circuit-breaker. The Acti 9 iID RCDs for DIN rails are fully coordinated with the iC60 moulded-case circuit-breakers to ensure complete protection of people and equipment against electric shock and fire, as well as improved continuity of operation. iID AC type RCDs provide:. Protection against electric shock on direct contact (≦ 30 mA). Protection against electric shock on indirect contact (≦ 100 mA). Protection of fixtures against fire (300 mA or 500 mA). iID-FI overload switches type Asi provide the following:. Protection against electric shock on direct contact (≦ 30 mA). Protection against electric shock with indirect contact (≦ 300 mA). Protection of fixtures against fire (300 mA or 500 mA). Increased immunity to electrical interference and contaminated or corrosive environments.

4. Schneider Electric CUTTER ELECT A9Z64440
The Schneider Electric A9Z64440 is an all-current-sensitive residual current circuit breaker (RCCB) designed for use in electrical installations. With a rated current of 40 A and a rated residual current of 300 mA, this 4-pole switch provides reliable protection against residual currents caused by various electrical disturbances. The Type B-SI is particularly suitable for applications that exhibit smooth DC residual currents, such as those generated by frequency converters or inverters. The switch operates at a supply voltage of 400 V AC and is suitable for use in 1- or 3-phase supply networks. Safety features include a mechanical fault indication (VisiTrip) and a safe contact indication (VisiSafe), which provide clear feedback on the device's status. The A9Z64440 complies with relevant standards and offers easy installation as well as the option to connect additional auxiliary modules.
- Mechanical fault indication (VisiTrip) to display tripping due to residual current
- Safe contact indication (VisiSafe) to ensure voltage-free status on the outgoing side
- Double connection terminals for connecting cables or busbars on both sides
- Easy removal of the individual device with the busbar installed, thanks to a front-accessible fastening element
- Type B-SI with integrated SI technology for greater resilience against electrical disturbances.

5. Schneider Electric TeSys GV2ME motor circuit breaker 6-10A
Range: TeSys
Connection type: Screw mounting
Series: GV2M
UL and CSA certified motor circuit-breaker - GV2-ME. Designed for use with TeSys contactors up to 15 kW. Provides short circuit and overload protection. Can be locked in the off position. Auxiliary contacts can be used to indicate shutdown or trip. Features screw terminal connections.

6. Schneider Electric Motor protection switch GV2ME10
Range: TeSys. Connection type: Screw fastening. Series: GV2M. UL and CSA. Motor circuit-breaker - GV2-ME. For use with the TeSys contactor up to 15 kW. Provides short-circuit and overload protection. Can be locked in the off position. Auxiliary contacts can be used to signal switch-off or tripping Screw connection.

7. Schneider Electric Circuit breaker K60N 1P, 16A, C A9K02116
The K60N 1P circuit breaker from Schneider Electric is a reliable and safe device designed to protect electrical systems. With a rated current of 16 A and a rated voltage of 230 V, this miniature circuit breaker provides an effective solution for circuit protection. The Type C of the circuit breaker is particularly suitable for applications with moderate inrush currents, making it versatile. The switching capacity of 6000 A ensures that the breaker reliably trips even under high fault currents. The circuit breaker is designed for mounting on a DIN rail and features a compact design that allows for easy installation. With an IP20 protection rating, it is suitable for use in dry indoor environments. The K60N 1P is a high-quality product manufactured in France, meeting the high standards of Schneider Electric.
- Type C for moderate inrush currents
- Switching capacity of 6000 A
- Mounting on DIN rail
- IP20 protection rating for dry indoor use.

Schneider Electric Circuit breaker K60N 1P, 16A, C A9K02116
8. Schneider Electric Miniature circuit-breaker K60N 1P, 10A, B A9K01110

Schneider Electric Miniature circuit-breaker K60N 1P, 10A, B A9K01110
9. Schneider Electric Ground fault circuit interrupter
The RCD from Schneider Electric is a highly advanced residual current device specifically designed for use in electrical installations. With a rated current of 40 A and a rated residual current of 30 mA, this 4-pole switch provides reliable protection against fault currents in single-phase or three-phase supply networks. The integrated SI technology (Type B-SI) ensures increased resistance to electrical disturbances, making it ideal for applications with frequency converters and inverters. The switch is equipped with a mechanical fault indication (VisiTrip) that allows for clear display of tripping events. Additionally, the safe contact indication (VisiSafe) ensures that there is no voltage present on the outgoing side. The device can be easily removed with the phase rail installed, and it can be expanded with additional auxiliary modules, making this RCD a flexible solution for various installation requirements.
- All-current sensitive protection for enhanced safety
- Mechanical fault indication (VisiTrip) for fault diagnosis
- Safe contact indication (VisiSafe) for voltage-free status
- Easy removal with installed phase rail
- Expandable with optional auxiliary modules for additional functions.

10. Schneider Electric GV2ME motor cct breaker,13-18A FLC range
Current range = 13 → 18 A
Number of poles = 3P
Range = TeSys
breaking capacity = 3 kA
Connection type = Screw mounting
Operating voltage = 690 V
Length = 89mm
width = 44.5mm
Depth = 78.2mm
Dimensions = 89 x 44.5mm x 78.2mm
Series = GV2M
UL and CSA. Motor circuit-breaker - GV2-ME. For use with TeSys contactor up to 15 kW - see (Part No. ; 394-9813 394-9813 ) for typical contactor Provides short-circuit and overload protection Can be locked in the off position Auxiliary contacts can be used to indicate shutdown or tripping Screw terminal.