Hager Ground fault circuit interrupter 1P+N 6kA B-6A 30mA ADS906D
6 pieces in stock at supplier
number of poles2
Product details
Hager RCD/MCB Switch ADS906D
Manufacturer: Hager
Designation: RCD/MCB 1P+N 6kA B-6A 30mA
Type: ADS906D
Number of poles (total): 2
Number of protected poles: 1
Rated voltage: 240 V
Rated insulation voltage Ui: 500 V
Rated impulse voltage withstand Uimp: 4 kV
Rated current: 6 A
Rated residual current: 0.03 A
Residual current type: A
Energy limitation class: 3
Power loss: 1.9 W
Rated short-circuit breaking capacity according to IEC 60947-2: 6 kA
Rated switching capacity Icn according to EN 61009-1: 6 kA
Tripping characteristic: instantaneous
Surge current withstand: 0.25 kA
Type of voltage: AC
Frequency: 50 Hz
Tripping characteristic: B
Switched neutral conductor: yes
With locking device: yes
Overvoltage category: 3
Degree of pollution: 2
Ambient temperature during operation: -25..40 °C
Width in modular units: 2
Installation depth: 68 mm
Flush-mounted installation: yes
False tripping protection: no
Protection class (IP): IP2X
Connectable conductor cross-section single-core: 1..25 mm²
Connectable conductor cross-section multi-core: 1..16 mm²
Hager RCD/MCB Switch ADS906D: additional details
Residual current circuit breaker 1P+N 6kA B-6A 30mA Type A QuickConnect. Residual current circuit breaker according to DIN EN 61009-1 (VDE 0664-20) with QuickConnect terminal, outgoing up to 20 A and incoming up to 63 A, blue test button and residual current indicator. Easy single extraction from the phase rail connection. Suitable for retrofitting additional devices. Labeling option directly on the device.
EAN: 3250611068112.
Circuit breaker type | Miniature circuit-breaker/residual current circuit-breaker combination |
Length | 320 mm |
Width | 230 mm |
number of poles | 1 |
Mounting type | Flush-mounted |
Item number | 20762451 |
Manufacturer | Hager |
Category | Residual-current device |
Manufacturer no. | ADS906D |
Release date | 4.5.2022 |
Circuit breaker type | Miniature circuit-breaker/residual current circuit-breaker combination |
Mounting type | Flush-mounted |
number of poles | 1 |
Tripping characteristic | B |
Rated current | 0.03 A |
Rated voltage | 240 V |
voltage type | AC |
Rated insulation voltage Ui | 500 V |
Residual current (rated differential current) | 0.03 A |
Protection type (IP code) | IPX2 |
Country of origin | France |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 320 mm |
Width | 230 mm |
Height | 370 mm |
Weight | 226 g |
Length | 10 cm |
Width | 8 cm |
Height | 4 cm |
Weight | 210 g |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Schneider Electric0 %
- 1.Siemens0 %
- 5.ABB0.1 %
- 6.Hager0.3 %
- 7.Steffen0.5 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- HagerNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- Schneider ElectricNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 3.Schneider Electric1.5 %
- 4.ABB2 %
- 5.Siemens2.7 %
- 6.Eaton3.6 %
- 7.Hager5.3 %