Hager Ground fault circuit interrupter 1P+N 6kA B-6A 30mA ADS906D

Delivered between Wed, 3.12. and Fri, 19.12.
6 pieces in stock at supplier
free shipping

number of poles2

Product details

Hager RCD/MCB Switch ADS906D

Manufacturer: Hager
Designation: RCD/MCB 1P+N 6kA B-6A 30mA
Type: ADS906D
Number of poles (total): 2
Number of protected poles: 1
Rated voltage: 240 V
Rated insulation voltage Ui: 500 V
Rated impulse voltage withstand Uimp: 4 kV
Rated current: 6 A
Rated residual current: 0.03 A
Residual current type: A
Energy limitation class: 3
Power loss: 1.9 W
Rated short-circuit breaking capacity according to IEC 60947-2: 6 kA
Rated switching capacity Icn according to EN 61009-1: 6 kA
Tripping characteristic: instantaneous
Surge current withstand: 0.25 kA
Type of voltage: AC
Frequency: 50 Hz
Tripping characteristic: B
Switched neutral conductor: yes
With locking device: yes
Overvoltage category: 3
Degree of pollution: 2
Ambient temperature during operation: -25..40 °C
Width in modular units: 2
Installation depth: 68 mm
Flush-mounted installation: yes
False tripping protection: no
Protection class (IP): IP2X
Connectable conductor cross-section single-core: 1..25 mm²
Connectable conductor cross-section multi-core: 1..16 mm²

Hager RCD/MCB Switch ADS906D: additional details
Residual current circuit breaker 1P+N 6kA B-6A 30mA Type A QuickConnect. Residual current circuit breaker according to DIN EN 61009-1 (VDE 0664-20) with QuickConnect terminal, outgoing up to 20 A and incoming up to 63 A, blue test button and residual current indicator. Easy single extraction from the phase rail connection. Suitable for retrofitting additional devices. Labeling option directly on the device.
EAN: 3250611068112.

Key specifications

Circuit breaker type
Miniature circuit-breaker/residual current circuit-breaker combination
Length
320 mm
Width
230 mm
number of poles
1
Mounting type
Flush-mounted
Item number
20762451

General information

Manufacturer
Hager
Category
Residual-current device
Manufacturer no.
ADS906D
Release date
4.5.2022

Circuit Breaker Features

Circuit breaker type
Miniature circuit-breaker/residual current circuit-breaker combination
Mounting type
Flush-mounted
number of poles
1
Tripping characteristic
B
Rated current
0.03 A
Rated voltage
240 V
voltage type
AC
Rated insulation voltage Ui
500 V
Residual current (rated differential current)
0.03 A
Protection type (IP code)
IPX2

Origin

Country of origin
France

Voluntary climate contribution

CO₂-Emission
Climate contribution

Scope of delivery

Items per sales unit
1 Piece

Product dimensions

Length
320 mm
Width
230 mm
Height
370 mm
Weight
226 g

Package dimensions

Length
10 cm
Width
8 cm
Height
4 cm
Weight
210 g

30-day right of return if unopened
24 Months Warranty (Bring-in)
1 additional offer

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 1.Schneider Electric
    0 %
  • 1.Siemens
    0 %
  • 5.ABB
    0.1 %
  • 6.Hager
    0.3 %
  • 7.Steffen
    0.5 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • Hager
    Not enough data
  • ABB
    Not enough data
  • Brennenstuhl
    Not enough data
  • Eaton
    Not enough data
  • Schneider Electric
    Not enough data

Unfortunately, we don't have enough data for this category yet.

Return rate

How often is a product of this brand in the «Residual-current device» category returned?

Source: Digitec Galaxus
  • 3.Schneider Electric
    1.5 %
  • 4.ABB
    2 %
  • 5.Siemens
    2.7 %
  • 6.Eaton
    3.6 %
  • 7.Hager
    5.3 %
Source: Digitec Galaxus