Doepke Fire protection switch DAFDD C100,032A

Delivered between Sat, 22.8. and Fri, 4.9.
More than 10 items ordered
free shipping

Product details

Fire protection switches, arc fault detection devices (AFDD), reduce the risk of fire due to defects in electrical installations. They disconnect the affected part of the system when serial and parallel arc faults occur. According to DIN VDE 0100-420, they are required for sleeping and living areas in daycare centers, nursing homes, and barrier-free apartments, as well as in fire-risk workplaces. The DAFDD 1 compactly combines the detection of arc faults with line and residual current protection. Contact position indicators and the residual current trip indicator provide a quick overview. The RCBO part offers protection against type A residual currents, as well as short circuits and overloads, independent of the mains voltage. Switches with a tripping characteristic of C are optimized for circuits with high inrush or peak currents. The standard version is optimized for monitoring circuits with a rated voltage of 230 V and a rated frequency of 50 Hz. Features: Combination device with three functions, two-pole, variable neutral conductor position, AFDD according to IEC/EN-62606, RCBO according to IEC/EN-61009, continuous self-monitoring of the AFD unit, mains voltage-independent tripping of the RCD and circuit breaker functions, AFDD trip reason display, contact position indicator, residual current trip indicator, compact size for all rated currents, high short-circuit resistance, terminal blocks with back protection, tristable latching slider for easy installation and removal, mounting type: quick fastening on mounting rail, installation position arbitrary, bottom feeding, application areas: protection of circuits in residential and purpose-built buildings as well as industrial plants with TN-S and TN-C-S networks. The use in systems with TN-C networks and for the protection of circuits where power electronics can cause smooth direct fault currents or fault currents with frequencies other than 50 Hz is excluded.

Key specifications

Circuit breaker type
FI-LS fire protection switch
Mounting type
Top-hat rail
number of poles
2
Length
70 mm
Width
54 mm

General information

Item number
22731289
Manufacturer
Doepke
Category
Residual-current device
Manufacturer No.
180315
Release date
19.10.2022
External links

Circuit Breaker Features

Circuit breaker type
FI-LS fire protection switch
Mounting type
Top-hat rail
number of poles
2
Tripping characteristic
C
Rated current
10 A
Rated current
0.03 A
Rated voltage
230 V
voltage type
AC
Residual current
0.03 A
Protection type (IP code)
IP20

Origin

Country of origin
Czech Republic

Voluntary climate contribution

CO₂ emissions
29.26 kg
Climate contribution
CHF 0.70

Scope of delivery

Items per sales unit
1 pcs.

Product dimensions

Length
70 mm
Width
54 mm
Height
70 mm

30-day right of return
24 Months Warranty (Bring-in)
1 additional offer

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • Doepke
    Not enough data
  • 1.Brennenstuhl
    0 %
  • 1.Eaton
    0 %
  • 1.Max Hauri
    0 %
  • 1.Siemens
    0 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • Doepke
    Not enough data
  • ABB
    Not enough data
  • Brennenstuhl
    Not enough data
  • Eaton
    Not enough data
  • Hager
    Not enough data

Unfortunately, we don't have enough data for this category yet.

Return rate

How often is a product of this brand in the «Residual-current device» category returned?

Source: Digitec Galaxus
  • Doepke
    Not enough data
  • 1.Max Hauri
    0.4 %
  • 2.Steffen
    0.5 %
  • 3.Eaton
    0.7 %
  • 4.Schneider Electric
    1.6 %
Source: Digitec Galaxus