Schneider Electric Over- or undervoltage between phases

Delivered between Fri, 5.6. and Fri, 12.6.
More than 10 pieces in stock at third-party supplier
Supplied by
Conrad CH
free shipping

Number of poles2

Product details

Monitoring Applications: Voltage
Supply Voltage: 120 to 277 V AC
Contact Arrangement: 2-pole switch
Electrical Phases: 3
Voltage Measurement Range: 114 to 329 V AC
Delay Time: 0.3 to 30 s
Width: 35 mm

UL, CSA, GL, C-Tick, GOST. NF EN 60255-6 and IEC 60255-6. RM17 UB3 and RM35 UB3 three-phase voltage monitors. Schneider Electric RM17/35 UB measuring and control relays for three-phase power supply monitor the correct sequence of phases L1, L2, and L3. It also monitors the total failure of one or more phases, asymmetry, as well as overvoltage and undervoltage with independent settings. In the event of a voltage fault, the relay will open at the end of the user-defined delay time. If the device is powered on with a measured fault, the relay remains open. The relay will open immediately in the event of a neutral conductor failure or phase loss. It checks its own power supply. Transparent front panel with hinges. Potentiometer selects voltages between phases. LED display of output status. DIN rail mounting.

Key specifications

Electric current output
5 A
Number of poles
2x

General information

Item number
9716117
Manufacturer
Schneider Electric
Category
Relays
Manufacturer No.
RM35UB3N30
Release date
24.9.2018

Relay properties

Electric current output
5 A
Switching function
Changer
Number of openers
0x
Number of closers
0x
Number of poles
2x

Origin

Country of origin
Indonesia

Sustainability

Manufacturer commitment
RE100SBTi

Voluntary climate contribution

CO₂ emissions
29.26 kg
Climate contribution
CHF 0.70

Product dimensions

Width
35 mm
Height
90 mm

30-day right of return
24 Months Warranty (Bring-in)
1 additional offer

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Relays» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 1.Metz Connect
    0 %
  • 1.Phoenix Contact
    0 %
  • 1.Schneider Electric
    0 %
  • 5.Finder
    0.1 %
  • 6.Eaton
    0.2 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • Schneider Electric
    Not enough data
  • 1.Shelly
    1 day
  • ABB
    Not enough data
  • Aqara
    Not enough data
  • Eaton
    Not enough data

Return rate

How often is a product of this brand in the «Relays» category returned?

Source: Digitec Galaxus
  • 7.Finder
    2.6 %
  • 8.Aqara
    3 %
  • 8.Schneider Electric
    3 %
  • 10.Eaton
    3.5 %
  • 11.Eltako
    3.6 %
Source: Digitec Galaxus