Siemens Dig.Industr. Circuit Breaker 5SY4108-7
Manufacturer: Siemens Dig.Industr.
Designation: Circuit Breaker C8A, 1-pole, T=70, 10kA
Type: 5SY4108-7
Installation Depth: 70 mm
Tripping Characteristic: C
Total Number of Poles: 1
Number of Protected Poles: 1
Rated Current: 8 A
Rated Voltage: 400 V
Rated Insulation Voltage Ui: 440 V
Rated Impulse Voltage Uimp: 4 kV
Rated Switching Capacity Icn according to EN 60898 at 230 V: 10 kA
Voltage Type: AC
Rated Switching Capacity Icn according to EN 60898 at 400 V: 10 kA
Rated Switching Capacity Icu according to IEC 60947-2 at 230 V: 20 kA
Rated Switching Capacity Icu according to IEC 60947-2 at 400 V: 20 kA
Frequency: 50 Hz
Energy Limitation Class: 3
Flush Mounting: No
Switchable Neutral Conductor: No
Overvoltage Category: 3
Degree of Pollution: 3
Additional Devices Possible: Yes
Width in Division Units: 1
Protection Class (IP): IP20
Ambient Temperature During Operation: -40..70 °C
Connectable Conductor Cross-Section Multi-Wire: 0.75..35 mm²
Connectable Conductor Cross-Section Single-Wire: 0.75..35 mm²
Explosion-Proof: No
Siemens Dig.Industr. Circuit Breaker 5SY4108-7: Additional Details
Circuit breaker 230/400V 10kA, 1-pole, C, 8A, T=70mm
The SENTRON 5SY circuit breakers provide safe short-circuit and overload protection for residential buildings, commercial buildings, and special industrial applications. Tool-free installation and removal of the device using a double slider. Any combination of conductors and busbars is possible through a double-chamber terminal. Simple wiring of the supply through the rear busbar. The 5SY circuit breakers are available in 1-, 2-, 3-, 4-, as well as 1+N and 3+N pole configurations. The complete accessories are uniformly applicable for all 5SY circuit breakers. Simply safe with SENTRON protection devices.
Circuit breaker type | Miniature circuit breaker |
Mounting type | Top-hat rail |
number of poles | 1 |
Length | 76 mm |
Width | 18 mm |
Item number | 18171840 |
Manufacturer | Siemens |
Category | Residual-current device |
Manufacturer no. | 5SY41087 |
Release date | 27.12.2021 |
Minimum order | 2 |
Colour | Grey |
Circuit breaker type | Miniature circuit breaker |
Mounting type | Top-hat rail |
number of poles | 1 |
Tripping characteristic | C |
Rated voltage | 400 V |
voltage type | AC |
Rated insulation voltage Ui | 440 V |
Protection type (IP code) | IP20 |
Country of origin | China |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 8.49 kg |
Climate contribution | CHF 0.21 |
Items per sales unit | 1 pcs. |
Length | 76 mm |
Width | 18 mm |
Height | 90 mm |
Weight | 162 g |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Brennenstuhl0 %
- 1.Eaton0 %
- 1.Siemens0 %
- 4.ABB0.1 %
- 4.Schneider Electric0.1 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- SiemensNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 3.Eaton0.7 %
- 4.Schneider Electric1.3 %
- 5.ABB2.1 %
- 6.Siemens3.4 %
- 7.Hager5.2 %