Siemens Ground fault circuit interrupter 1 pole 16 A
More than 10 items in stock at supplier
Product details
Siemens RCD/MCB, 6 kA, 1P+N, Type A, 30 mA, B-Characteristic, In: 16 A, Un AC: 230 V. RCD/MCB for combined short-circuit protection and touch protection. The patented RCD/MCBs from Siemens - an essential component of the SENTRON protective devices for electrical installations - enable combined personal, fire, and line protection in just one device. In addition to detecting fault currents, they also provide reliable protection against short circuits and overloads thanks to the integrated overcurrent protection device. The Siemens RCD/MCBs, as a combination of residual current and circuit breakers, stand out primarily due to: 1. Increased operational safety and system availability thanks to the separate disconnection of the affected circuit. 2. Whether sinusoidal alternating fault currents or smooth direct fault currents - Siemens offers the right type for all requirements, as well as special versions. 3. Reliable safety during installation thanks to standard integrated grip and touch protection. 4. Tool-free removal from the DIN rail or busbar connection through convenient slider manual operation. 5. Clearly visible switching position indicator. 6. Data matrix code on the front of the device provides quick and easy access to all information about the RCD/MCB. 7. Be normatively protected: The RCD/MCBs comply with the regulations of DIN VDE. 8. Optimal technology for your safety - only from Siemens. Siemens offers a comprehensive portfolio of protection, switching, measuring, and monitoring devices, as well as distribution systems for safe and efficient electrical infrastructure in buildings and industry.
Circuit breaker type | Fault current circuit breaker |
Length | 77 mm |
Width | 36 mm |
mounting style | Top-hat rail |
number of poles | 1 |
Item number | 8411127 |
Manufacturer | Siemens |
Category | Residual-current device |
Manufacturer no. | 5SU1356-6KK16 |
Release date | 20.4.2018 |
External links |
Colour | Grey |
Exact colour description | Grey |
Circuit breaker type | Fault current circuit breaker |
mounting style | Top-hat rail |
number of poles | 1 |
Tripping characteristic | Sluggish --- |
Rated current | 16 A |
Rated current | 0.03 A |
Rated voltage | 230 V |
voltage type | AC |
Rated insulation voltage Ui | 264 V |
Residual current (rated differential current) | 0.03 A |
Protection type (IP code) | IP20 |
Country of origin | Germany |
Manufacturer commitment | RE100, SBTi |
Manufacturer compensation | According to RE100, the manufacturer Siemens fully compensates for its energy consumption, leading to a reduction in emissions. |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 77 mm |
Width | 36 mm |
Height | 90 mm |
Weight | 272 g |
Length | 10 cm |
Width | 9 cm |
Height | 5 cm |
Weight | 260 g |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Brennenstuhl0 %
- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0.2 %
- 5.ABB0.3 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- SiemensNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 3.ABB1.6 %
- 4.Legrand1.9 %
- 5.Siemens2 %
- 6.Schneider Electric2.1 %
- 7.Eaton4.3 %