Product details
Schneider Electric Circuit Breaker 18767
Manufacturer: Schneider Electric
Designation: Circuit Breaker 3p 80A B NG125L
Type: 18767
Installation Depth: 47 mm
Tripping Characteristic: B
Number of Poles (total): 3
Number of Protected Poles: 3
Rated Current: 80 A
Rated Voltage: 400 V
Rated Insulation Voltage Ui: 690 V
Rated Impulse Voltage Uimp: 8 kV
Voltage Type: AC/DC
Rated Breaking Capacity Icu according to IEC 60947-2 at 230 V: 100 kA
Rated Breaking Capacity Icu according to IEC 60947-2 at 400 V: 50 kA
Frequency: 50..60 Hz
Flush Mounting: no
Switching Neutral Conductor: no
Overvoltage Category: 4
Degree of Pollution: 3
Additional Devices Possible: yes
Width in Division Units: 4.5
Protection Class (IP): IP20
Ambient Temperature during Operation: -30..70 °C
Connectable Conductor Cross-Section Multi-Wire: 10..50 mm²
Connectable Conductor Cross-Section Single-Wire: 16..70 mm²
Explosion-Proof: no
The Acti 9 NG125L circuit breaker has a rated current of 80A and a B characteristic. The operating voltage is 380-415V AC, and the insulation voltage is 690V AC. It protects the circuit against short-circuit and overload currents. The tripping is indicated by the middle position of the switch lever and a red mechanical display on the front of the device. A test button for checking the tripping mechanism is available. The switch can be fed from the top or bottom and features a spring mechanism for low-wear contact switching. The technology of the tripping unit is thermomagnetic. Additionally, stackable auxiliary modules (optional) are available, allowing for the display of switching status, fault tripping, operating current tripping, undervoltage tripping, and overvoltage tripping. The NG125L circuit breaker complies with the IEC/EN 60947-2 standards. EAN: 3303430187677.
Circuit breaker type | Circuit breaker |
Width | 45 mm |
mounting style | Flush-mounted |
number of poles | 3 |
Item number | 36767861 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer no. | 18767 |
Release date | 28.6.2023 |
Circuit breaker type | Circuit breaker |
mounting style | Flush-mounted |
number of poles | 3 |
Tripping characteristic | B |
Rated current | 80 A |
Rated voltage | 400 V |
voltage type | AC/DC |
Rated insulation voltage Ui | 690 V |
Protection type (IP code) | IP20 |
Country of origin | France |
Manufacturer commitment | RE100, SBTi |
Manufacturer compensation | According to RE100, the manufacturer Schneider Electric fully compensates for its energy consumption, leading to a reduction in emissions. |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Width | 45 mm |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Brennenstuhl0 %
- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0.1 %
- 5.Hager0.2 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- Schneider ElectricNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 2.ABB1.6 %
- 2.Brennenstuhl1.6 %
- 2.Schneider Electric1.6 %
- 5.Siemens2.1 %
- 6.Eaton4 %