Current range: 1 to 1.6 A
Number of poles: 3P
Series: TeSys
Connection type: Spring terminal
Operating voltage: 500 V
Length: 89 mm
Width: 44.5 mm
Depth: 78.2 mm
Dimensions: 89 x 44.5 x 78.2 mm
Series: GV2M

IEC/EN 60947-2 and IEC/EN 60947-4-1. Schneider Electric motor protection circuit breaker GV2ME. The GV2ME motor protection circuit breakers are 3-pole thermomagnetic circuit breakers specifically designed for the control and protection of motors. These circuit breakers are designed for connection with spring terminal connections, ensuring a secure, permanent, and durable connection that withstands extreme environmental conditions, vibrations, and shocks, and is even more effective when conductors are used without ferrules. Each connection can accommodate two independent conductors. Spring terminals with push-button operation are also usable for disconnection.

Key specifications

Circuit breaker type
Circuit breaker
number of poles
3
Length
78.20 mm
Width
45 mm

General information

Item number
9728100
Manufacturer
Schneider Electric
Category
Residual-current device
Manufacturer No.
GV2ME063
Release date
24.9.2018

Circuit Breaker Features

Circuit breaker type
Circuit breaker
number of poles
3
Tripping characteristic
Sluggish ---
Rated current
0.01 A
voltage type
AC/DC
Protection type (IP code)
IP20

Origin

Country of origin
France

Sustainability

Manufacturer commitment
RE100SBTi

Voluntary climate contribution

CO₂ emissions
18.08 kg
Climate contribution
CHF 0.43

Product dimensions

Length
78.20 mm
Width
45 mm
Height
101 mm

30-day right of return
24 Months Warranty (Bring-in)

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 1.Max Hauri
    0 %
  • 4.ABB
    0.1 %
  • 4.Schneider Electric
    0.1 %
  • 4.Siemens
    0.1 %
  • 7.Hager
    0.3 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • 1.Hager
    0 days
  • ABB
    Not enough data
  • Brennenstuhl
    Not enough data
  • Eaton
    Not enough data
  • Max Hauri
    Not enough data

Return rate

How often is a product of this brand in the «Residual-current device» category returned?

Source: Digitec Galaxus
  • 1.Max Hauri
    0.3 %
  • 2.Steffen
    0.8 %
  • 3.Schneider Electric
    1.7 %
  • 4.Eaton
    1.9 %
  • 5.ABB
    3.7 %
Source: Digitec Galaxus