Eaton Moeller) RCD switch FRCMM-40/2/003-G/F

Delivered between Sat, 9.8. and Sat, 30.8.

Product details

The Eaton RCD FRCMM-40/2/003-G/F is a compact residual current device designed for a wide range of applications. It provides both fault and additional protection and is available in various rated currents. This switch features a true contact position indicator and allows for automatic reset, making it particularly user-friendly. Additionally, it is suitable for outdoor use, including construction site and outdoor distribution boards, and can withstand temperatures as low as -25°C. With its robust design and extensive accessory options, this RCD is a reliable choice for protecting electrical installations.

  • Suitable for outdoor use down to -25°C
  • True contact position indicator for enhanced safety
  • Automatic reset for user convenience
  • Extensive range of accessories available
  • Versatile for fault and additional protection.

Key specifications

Circuit breaker type
Fault current circuit breaker
Width
2 mm
mounting style
Top-hat rail
number of poles
2
Item number
31967755

General information

Manufacturer
Eaton
Category
Residual-current device
Manufacturer no.
187367
Release date
28.6.2023

Circuit Breaker Features

Circuit breaker type
Fault current circuit breaker
mounting style
Top-hat rail
number of poles
2
Rated current
40 A
Rated voltage
240 V
voltage type
AC
Rated insulation voltage Ui
440 V
Residual current (rated differential current)
0.03 A
Protection type (IP code)
IP20

Sustainability

Manufacturer commitment
SBTi

Voluntary climate contribution

CO₂-Emission
Climate contribution

Scope of delivery

Items per sales unit
1 Piece

Product dimensions

Width
2 mm

30-day right of return if unopened
24 Months Warranty (Bring-in)

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 1.Schneider Electric
    0 %
  • 1.Siemens
    0 %
  • 4.Eaton
    0.2 %
  • 5.ABB
    0.3 %
  • 5.Hager
    0.3 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • Eaton
    Not enough data
  • ABB
    Not enough data
  • Brennenstuhl
    Not enough data
  • Hager
    Not enough data
  • Schneider Electric
    Not enough data

Unfortunately, we don't have enough data for this category yet.

Return rate

How often is a product of this brand in the «Residual-current device» category returned?

Source: Digitec Galaxus
  • 2.Brennenstuhl
    1.4 %
  • 4.Siemens
    2 %
  • 5.Schneider Electric
    2.1 %
  • 6.Eaton
    4.3 %
  • 7.Hager
    4.7 %
Source: Digitec Galaxus