Doepke Ground fault circuit interrupter
Product details
The Doepke RCD is a highly advanced residual current device designed for use in single-phase and three-phase networks. These devices provide reliable protection for people, animals, and electrical installations by immediately interrupting the power supply in the event of dangerously high fault currents. The compact switches are available in two- or four-pole versions and are characterized by their high sensitivity to various types of fault currents. They are suitable for rated currents up to 125 A and feature large double-deck terminals that can accommodate thicker conductor cross-sections. The user-friendly reset position of the multifunction switch knob simplifies troubleshooting, while the free labeling software supports the labeling of the switches. These devices are not only shock current and lightning resistant but are also optimized for special applications, such as monitoring charging facilities for electric vehicles.
- Two- or four-pole versions for flexible applications
- Increased sensitivity to pulse and alternating fault currents
- Suitable for rated currents up to 125 A
- User-friendly troubleshooting with multifunction switch knob
- Additional function for detecting smooth DC fault currents in special versions.
Circuit breaker type | Fault current circuit breaker |
number of poles | 4 |
Item number | 41967728 |
Manufacturer | Doepke |
Category | Residual-current device |
Manufacturer No. | 09154814 |
Release date | 10.1.2024 |
Circuit breaker type | Fault current circuit breaker |
number of poles | 4 |
Rated current | 125 A |
Rated current | 0.03 A |
Rated voltage | 400 V |
voltage type | AC |
Insulation voltage (Ui) | 400 V |
Residual current | 0.03 A |
Protection type (IP code) | IP20 |
Country of origin | Germany |
Items per sales unit | 1 pcs. |
Height | 69 mm |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- DoepkeNot enough data
- 1.Brennenstuhl0 %
- 1.Eaton0 %
- 1.Max Hauri0 %
- 1.Siemens0 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- DoepkeNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- DoepkeNot enough data
- 1.Steffen0.6 %
- 2.Eaton0.7 %
- 2.Max Hauri0.7 %
- 4.Schneider Electric1.4 %