Product details
The Doepke RCD is a highly advanced residual current device designed for use in single-phase networks. It provides reliable protection for people, animals, and electrical systems by automatically disconnecting the power supply in the event of dangerously high fault currents. With a compact design that occupies only two modular units, this switch is ideal for mounting on DIN rails. The devices are available in various versions and offer high immunity to transient fault currents, which increases system availability. The voltage-independent tripping ensures that the switch operates reliably even during fluctuations in the power supply. Additionally, the tripped position of the multifunctional switch knob facilitates troubleshooting, while the free labeling software supports the labeling of the switches.
- Two-pole residual current device for single-phase networks
- High immunity to transient fault currents
- Voltage-independent tripping for reliable operation
- Easy troubleshooting through the tripped position of the multifunctional switch knob.
Circuit breaker type | Fault current circuit breaker |
Length | 69 mm |
Width | 2 mm |
mounting style | Top-hat rail |
number of poles | 2 |
Item number | 36776163 |
Manufacturer | Doepke |
Category | Residual-current device |
Manufacturer no. | 09134609 |
Release date | 28.6.2023 |
Circuit breaker type | Fault current circuit breaker |
mounting style | Top-hat rail |
number of poles | 2 |
Tripping characteristic | A |
Rated current | 40 A |
Rated voltage | 230 V |
voltage type | AC |
Rated insulation voltage Ui | 400 V |
Residual current (rated differential current) | 0.03 A |
Protection type (IP code) | IP20 |
Country of origin | Germany |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 69 mm |
Width | 2 mm |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- DoepkeNot enough data
- 1.Brennenstuhl0 %
- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0.2 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- DoepkeNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- DoepkeNot enough data
- 1.Steffen0.3 %
- 2.ABB1.4 %
- 2.Brennenstuhl1.4 %
- 4.Legrand1.9 %