Doepke Ground fault circuit interrupter
Product details
The Doepke RCD is a highly advanced residual current device designed for use in single-phase and three-phase networks. It provides reliable protection for people, animals, and electrical systems by automatically disconnecting the power supply in the event of dangerously high fault currents. With a compact design that occupies only four modular units, this switch is suitable for both private and commercial applications. The devices are available in various versions and offer high short-circuit resistance as well as the ability to connect large conductor cross-sections through the double-deck terminals on both sides. The integrated switching position indicator and the viewing window for labeling stickers facilitate handling and maintenance. The multifunctional switching knob allows for easy operation and troubleshooting, while the independent tripping mechanism from the mains and auxiliary voltage provides additional safety.
- Two- or four-pole design for flexible applications
- High short-circuit resistance for increased safety
- Double-deck terminals on both sides for large conductor cross-sections
- Multifunctional switching knob with three positions for easy operation
- Viewing window for individual labeling and easy identification.
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 4 |
Length | 69 mm |
Item number | 36757082 |
Manufacturer | Doepke |
Category | Residual-current device |
Manufacturer No. | 09137945 |
Release date | 28.6.2023 |
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 4 |
Rated current | 40 A |
Rated current | 0.5 A |
Rated voltage | 500 V |
voltage type | AC |
Insulation voltage (Ui) | 500 V |
Residual current | 0.50 A |
Protection type (IP code) | IP20 |
Country of origin | Germany |
Length | 69 mm |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- DoepkeNot enough data
- 1.Brennenstuhl0 %
- 1.Eaton0 %
- 1.Max Hauri0 %
- 1.Siemens0 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- DoepkeNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- DoepkeNot enough data
- 1.Steffen0.6 %
- 2.Eaton0.7 %
- 2.Max Hauri0.7 %
- 4.Schneider Electric1.4 %