Product details

RCBOs combine residual current and circuit breakers in one device (RCCB/MCB combination). They protect people from residual currents and equipment from short circuits and overloads. The DRCBO 4 has a rated breaking capacity of 6 kA. In addition to a tripped indicator, it also features a labeling window. Type B+ residual current circuit breakers detect smooth direct residual currents as well as all other residual currents at frequencies up to 20 kHz. The required operating voltage is derived from the mains voltage, ensuring correct voltage supply when the voltage between the mains conductors is >= 50 V. Pulsed and alternating residual currents are detected independently of the mains voltage. Switches with tripping characteristics B are the standard protection for lighting and socket circuits. Standard switches are designed for circuits with a rated voltage of 230 V or 400 V and a rated frequency of 50 Hz. Features include: all-current sensitivity for residual currents with frequencies from 0 Hz (smooth direct current) to 20 kHz, independent tripping for type A residual currents, compact size for all rated currents, switching position indicator, separate indication of the tripping reason, terminal blocks with a wide clamping cross-section range on both connection sides, neutral conductor on the right, labeling window, mounting type: quick fastening on mounting rails, installation position flexible, preferred supply from above, application areas: commercial and industrial installations with TT, TN-S, and TN-C-S systems, where power electronics devices are used without galvanic isolation, such as frequency converters, switch-mode power supplies, high-frequency current converters, photovoltaic or UPS systems with transformerless inverters, RCBOs of type B+ and type B with NK characteristics should be used there.

Key specifications

Circuit breaker type
Miniature circuit-breaker/residual current circuit-breaker combination
number of poles
2
Tripping characteristic
B
Rated current
32 A
Length
67 mm
Width
111.13 mm

General information

Item number
33800197
Manufacturer
Doepke
Category
Residual-current device
Manufacturer No.
09949307
Release date
17.5.2023

Circuit Breaker Features

Circuit breaker type
Miniature circuit-breaker/residual current circuit-breaker combination
number of poles
2
Tripping characteristic
B
Rated current
32 A
Rated voltage
230 V
voltage type
ACAC/DC
Insulation voltage (Ui)
440 V
Residual current
0.03 A
Protection type (IP code)
IP20

Origin

Country of origin
Germany

Voluntary climate contribution

CO₂ emissions
18.08 kg
Climate contribution
CHF 0.43

Scope of delivery

Items per sales unit
1 pcs.

Product dimensions

Length
67 mm
Width
111.13 mm

30-day right of return
24 Months Warranty (Bring-in)

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • Doepke
    Not enough data
  • 1.Brennenstuhl
    0 %
  • 1.Eaton
    0 %
  • 1.Schneider Electric
    0 %
  • 4.Siemens
    0.1 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • Doepke
    Not enough data
  • 1.Hager
    0 days
  • ABB
    Not enough data
  • Brennenstuhl
    Not enough data
  • Eaton
    Not enough data

Return rate

How often is a product of this brand in the «Residual-current device» category returned?

Source: Digitec Galaxus
  • Doepke
    Not enough data
  • 1.Max Hauri
    0.3 %
  • 2.Steffen
    0.8 %
  • 3.Schneider Electric
    1.5 %
  • 4.Eaton
    2.6 %
Source: Digitec Galaxus