Arc Fault Detection Device (AFDD) with Residual Current Circuit Breaker (RCBO) according to IEC/EN 62606 (VDE 0665-10) and IEC/EN 61009-1 (VDE 0664-20), IEC/EN 61009-2-1 (VDE 0664-21) provides protection against series and parallel arc faults, overcurrent protection (overload or short circuit), protection for sinusoidal alternating currents and pulsating currents with smooth residual direct current of up to 6 mA to ground. It also offers fault protection (protection against indirect contact) and additional protection (with I?n = 30 mA). Overvoltage protection (only for AFDD internally) and protection against electrically ignited fires according to DIN VDE 0100-420.

Mandatory application areas according to DIN VDE 0100-420 are in single-phase AC systems with In = 16 A in sleeping or living areas of homes and day care facilities for children, disabled or elderly people, or in barrier-free apartments, as well as in rooms or locations with fire risk (with special fire hazards, fire-prone workplaces), predominantly/mainly made of combustible building materials. Threat to irreplaceable goods - cultural assets of particularly high value and in single-phase final circuits that supply electrical equipment in the mentioned areas or traverse these areas. The use of AFDDs is recommended in rooms with sleeping facilities, in rooms or locations with fire-spreading structures, and in final circuits with high connection power.

In general, the AFDD is also recommended to enhance fire protection against electrically ignited fires. LED indicator to identify the cause of tripping. Top or bottom feed is flexible, cross-wiring to RCDs in the rear terminal area is possible. Accessories of the pro M compact® system can be mounted. Rated switching capacity according to IEC/EN 61009 Icn=10kA. AFDD+RCBO DS-ARC1M is single-pole protected (LS), double-pole switching.

Key specifications

Circuit breaker type
Fault current circuit breakerMiniature circuit breaker
Mounting type
Top-hat rail
number of poles
2
Length
69 mm

General information

Item number
31990388
Manufacturer
ABB
Category
Residual-current device
Manufacturer no.
2CSA275103R1165
Release date
24.10.2022

Circuit Breaker Features

Circuit breaker type
Fault current circuit breakerMiniature circuit breaker
Mounting type
Top-hat rail
number of poles
2
Tripping characteristic
B
Rated current
16 A
Rated current
0.03 A
Rated voltage
230 V
voltage type
AC
Residual current (rated differential current)
0.03 A
Protection type (IP code)
IP40

Origin

Country of origin
Italy

Sustainability

Manufacturer commitment
SBTi

Voluntary climate contribution

CO₂ emissions
18.08 kg
Climate contribution
CHF 0.43

Product dimensions

Length
69 mm

30-day right of return
24 Months Warranty (Bring-in)

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 1.Eaton
    0 %
  • 1.Siemens
    0 %
  • 4.ABB
    0.1 %
  • 4.Schneider Electric
    0.1 %
  • 6.Hager
    0.2 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • ABB
    Not enough data
  • Brennenstuhl
    Not enough data
  • Eaton
    Not enough data
  • Hager
    Not enough data
  • Max Hauri
    Not enough data

Unfortunately, we don't have enough data for this category yet.

Return rate

How often is a product of this brand in the «Residual-current device» category returned?

Source: Digitec Galaxus
  • 3.Max Hauri
    0.8 %
  • 4.Schneider Electric
    1.4 %
  • 5.ABB
    2 %
  • 6.Siemens
    3.4 %
  • 7.Hager
    4.9 %
Source: Digitec Galaxus