ABB Stotz S&J Contactor UA30-30-10-80

Manufacturer: ABB Stotz S&J
Designation: Contactor
Type: UA30-30-10-80
Rated control supply voltage Us at AC 50 Hz: 220..230 V
Rated control supply voltage Us at AC 60 Hz: 230..240 V
Type of voltage for actuation: AC
Number of auxiliary contacts as normally open: 1
Connection type for main circuit: Screw connection
Number of normally open contacts as main contacts: 3
Rated reactive power at 400 V, 50 Hz: 27.5 kvar

The 3-pole contactors UA30-30-10 for capacitor switching can be used in systems where the peak current reaches a maximum of 100 times the rated effective current. Their electrical lifespan is 100,000 switching cycles. The 3-pole contactors of the UA30 series are designed in a block structure.

  • Main poles and auxiliary contact blocks: 3 main poles, with one built-in normally open auxiliary contact; installation of additional auxiliary contact blocks for front and side mounting is possible.
  • Control circuit: AC operation with laminated magnetic circuit
  • Accessories: A wide range of additional accessories is available.

Key specifications

number of poles
3
Length
108.30 mm
Width
54 mm

General information

Item number
30616206
Manufacturer
ABB
Category
Residual-current device
Manufacturer No.
1SBL281022R8010
Release date
14.7.2021

Circuit Breaker Features

Mounting type
Screw fastening
number of poles
3
Rated voltage
230 V
voltage type
AC

Origin

Country of origin
China

Sustainability

Manufacturer commitment
RE100

Voluntary climate contribution

CO₂ emissions
18.08 kg
Climate contribution
CHF 0.43

Scope of delivery

Items per sales unit
1 pcs.

Product dimensions

Length
108.30 mm
Width
54 mm

30-day right of return
24 Months Warranty (Bring-in)
1 additional offer

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 1.Max Hauri
    0 %
  • 1.Siemens
    0 %
  • 5.ABB
    0.1 %
  • 5.Schneider Electric
    0.1 %
  • 7.Hager
    0.3 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • ABB
    Not enough data
  • Brennenstuhl
    Not enough data
  • Eaton
    Not enough data
  • Hager
    Not enough data
  • Max Hauri
    Not enough data

Unfortunately, we don't have enough data for this category yet.

Return rate

How often is a product of this brand in the «Residual-current device» category returned?

Source: Digitec Galaxus
  • 2.Max Hauri
    0.7 %
  • 4.Schneider Electric
    1.4 %
  • 5.ABB
    1.8 %
  • 6.Siemens
    2.7 %
  • 7.Hager
    4.6 %
Source: Digitec Galaxus