ABB Automatic circuit breaker S200 type D 4A 6kA
More than 10 pieces in stock at supplier
Product details
Range: System M Pro
Series: S200
Number of poles: 1
Rated current: 4 A
Tripping characteristic: Type D
AC rated voltage: 253 V
DC rated voltage: 72 V
Breaking capacity: 6 kA
Length: 88 mm
Depth: 75.8 mm
Classic and System Pro M products cannot be mixed and they have no common accessories. System Pro M series products can only be mounted in new type Protecta distribution boxes. Type D, 1-pole, 6 kA - System Pro M. Type D provides a short-circuit response at 10 to 13 times the rated current, making it ideal for circuits with higher inrush currents such as motor control and fluorescent lighting in industrial buildings, where faster types often cause inadvertent false tripping. DIN rail mounted in accordance with BS EN 60898. Operating temperature range: -25 °C to +55 °C. Standard width: 17.5 mm. Maximum operating voltage: 440 Vac, 60 Vdc.
Circuit breaker type | Miniature circuit breaker |
Mounting type | Top-hat rail |
number of poles | 1 |
Length | 88 mm |
Width | 17.50 mm |
Item number | 9729633 |
Manufacturer | ABB |
Category | Residual-current device |
Manufacturer No. | 2CDS251001R0041 |
Release date | 24.9.2018 |
Colour | Multicoloured |
Exact colour description | multicolour |
Circuit breaker type | Miniature circuit breaker |
Mounting type | Top-hat rail |
number of poles | 1 |
Tripping characteristic | D |
Rated voltage | 72 V |
voltage type | AC/DC |
Protection type (IP code) | IP20 |
Country of origin | Germany |
Manufacturer commitment | RE100 |
CO₂ emissions | 18.08 kg |
Climate contribution | CHF 0.43 |
Items per sales unit | 1 pcs. |
Length | 88 mm |
Width | 17.50 mm |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Max Hauri0 %
- 1.Siemens0 %
- 5.ABB0.1 %
- 5.Schneider Electric0.1 %
- 7.Hager0.3 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Max HauriNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 3.Eaton0.7 %
- 4.Schneider Electric1.5 %
- 5.Siemens2.6 %
- 6.ABB3.2 %
- 7.Hager4.7 %