With this unit, the desired humidity can be set, e.g. 50 %. When this value is reached, I expected the unit to switch off and switch on again automatically when the humidity rises above the selected 50 %. However, my unit continues to run until the water tank is full. Have you had any other experiences? Or is there anything special to note about the operation?
Mine runs perfectly and only when necessary. I have also connected it to a timer so that I can use the low tariff.
The unit always checks in 30-minute intervals. So if a set limit value is exceeded or undershot 1 minute after the last test, the box will not check again until 29 minutes...
I have no problems with my device. It works exactly as described in the instructions.