Hello all, The data sheet says frequency 60 Hz. However, on the data sheet it says 50 - 60 Hz, what applies now? 60 Hz would be unusable for the whole of Europe ... Thank you in advance for clarification.
According to the instruction manual, the 60Hz version only has 120V, while the 50Hz version supplies 230-240V. Since I have not found a switch, I assume that there are 2 versions of this generator. Since the generator is advertised here with an output voltage of AC 240V, I assume that it runs at 50Hz. So you are right, 60Hz would be useless for Europe (except for consumers who can handle this input voltage).
Actually, though, Galaxis needs to confirm that they sell the 50Hz version here. Yes, I bought this unit, but I must confess that I did not measure it. The consumer I had connected as a test would also have coped with 60Hz.