ABB Stotz S&J RCD Block DDA204A-40/0.3
Manufacturer: ABB Stotz S&J
Designation: RCD Block 4p, 40A, 300mA
Type: DDA204A-40/0.3
Rated Voltage: 230..400 V
Rated Current: 40 A
Adjustable Rated Residual Current: no
Rated Residual Current: 0.3 A
Max. Delay Time: 0 ms
Adjustable Delay Time: no
Number of Poles: 4
Residual Current Type: A
Frequency: 50/60 Hz
Rated Insulation Voltage Ui: 500 V
Rated Impulse Voltage Uimp: 4 kV
Connectable Conductor Cross-Section Single Wire: 16 mm²
Connectable Conductor Cross-Section Multi-Wire: 16 mm²
False Tripping Protection: no
With Locking Mechanism: yes
Protection Class (IP): IP2X
Ambient Temperature During Operation: -25..55 °C
The RCD block (RCU) is designed for customer-side installation with circuit breakers of the S200 series. The resulting RCD/MCB combination (RCBOs) provides protection for persons and property as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They ensure protection for 1P+N, 2P, 3P, 3P+N, or 4P circuits against overload and short-circuit currents, protection for sinusoidal alternating currents and pulsating currents with a smooth DC fault current component of up to 6 mA to earth. Additionally, they provide fault protection (protection against indirect contact), supplementary protection (with I?n = 30 mA), and fire protection (with I?n = 300 mA). They comply with the product standard IEC/EN 61009 Annex G. Application areas include household, commercial, and industrial applications. The extensive range of accessories provides everything you need for your installation tasks. The rated short-circuit capacity is 6 kA for S200 MCBs, 10 kA for S200 M, and 25 kA for S200 P.
Circuit breaker type | Residual current protection block |
number of poles | 4 |
Mounting type | Top-hat rail |
Item number | 9717670 |
Manufacturer | ABB |
Category | Residual-current device |
Manufacturer no. | 2CSB204101R3400 - DDA204A-40/0,3 |
Release date | 24.9.2018 |
Circuit breaker type | Residual current protection block |
Mounting type | Top-hat rail |
number of poles | 4 |
Tripping characteristic | A |
Rated current | 40 A |
Rated current | 0.3 A |
Rated voltage | 400 V |
voltage type | AC/DC |
Rated insulation voltage Ui | 500 V |
Residual current (rated differential current) | 0.30 A |
Protection type (IP code) | IPX2 |
Country of origin | Italy |
Manufacturer commitment | SBTi |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec GalaxusHow many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec GalaxusUnfortunately, we don't have enough data for this category yet.
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus