Victron Energy Argodiode 80-2SC, 2 batteries 80A
In Detail
Argo Battery Isolator Diodes 80-2SC
Battery isolator diodes allow multiple batteries to be charged simultaneously from a single power source without the individual batteries being connected to each other. For example, the onboard network battery can be loaded without simultaneously discharging the starter battery. By utilizing modern Schottky diodes, the voltage loss is kept low, approximately 0.3 V at low currents and around 0.45 V at nominal current.
All models in this series are equipped with a compensation diode that slightly increases the output voltage of the alternator to compensate for the voltage loss caused by the Schottky diodes.
If the isolator diode is connected directly into the wiring between the alternator and battery without any additional measures, a voltage loss occurs that leads to incomplete charging and premature aging of the battery. Some types of generators require a DC voltage at the B+ terminal for initial excitation. The connection between the battery and generator creates a direct cable link. However, the isolator diode prevents current backflow, which means the generator will not start.
The new 802AC battery isolator diode features a special current-limited connection for initial excitation when the generator is started.