Product details

Supply voltage: 24 Vdc, 240 Vac
Number of channels: 1, 2
Auxiliary contacts: 2
Function: Light beam/light curtain
Safety category ISO 13849-1: 4
SIL: 3
PL: E
Safety contacts: 7
Range: Preventa
Connection type: Screw fastening
Length: 99 mm

BG, UL, CSA. IEC 204-1; EN 292; EN 418; EN 60204-1; EN 1088. XPS AR for light curtains and emergency stop switches. Includes 7 safety relay outputs (normally closed) and 2 potential-free signal outputs (normally open), 4 solid-state output signals that replicate the LED signaling on the front of the module. Monitoring of the start button or automatic start-up process. 24 Vdc option available in every supply voltage version. Compact housing, 90 mm. Can be used for monitoring light curtains (Type 4) with semiconductor outputs in accordance with EN61496-01. The letter "P" at the end of the part number indicates that the product features removable terminal blocks.

Key specifications

input voltage
24 V

General information

Item number
9717333
Manufacturer
Schneider Electric
Category
Relays
Manufacturer No.
XPSAR371144
Release date
24.9.2018

Relay properties

input voltage
24 V

Origin

Country of origin
Indonesia

Sustainability

Manufacturer commitment
RE100SBTi

Voluntary climate contribution

CO₂ emissions
29.26 kg
Climate contribution
CHF 0.70

Product dimensions

Length
114 mm
Width
90 mm
Height
99 mm

30-day right of return
24 Months Warranty (Bring-in)

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Relays» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 1.Metz Connect
    0 %
  • 1.Phoenix Contact
    0 %
  • 1.Schneider Electric
    0 %
  • 5.Finder
    0.1 %
  • 6.Eaton
    0.2 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • Schneider Electric
    Not enough data
  • 1.Shelly
    1 day
  • ABB
    Not enough data
  • Aqara
    Not enough data
  • Eaton
    Not enough data

Return rate

How often is a product of this brand in the «Relays» category returned?

Source: Digitec Galaxus
  • 7.Finder
    2.6 %
  • 8.Aqara
    3 %
  • 8.Schneider Electric
    3 %
  • 10.Eaton
    3.5 %
  • 11.Eltako
    3.6 %
Source: Digitec Galaxus