Schneider Electric Overload relay 7A 24VAC/DC

Currently out of stock
Free shipping starting at 50.–

Product details

FLC Motor power: 1.2 to 7 A
Rated contact current: 7 A
Design type: TeSys
Rated contact voltage: 690 Vac
Mounting type: Direct contactor
Supply voltage: 24 Vac/dc
Series: LR97 D
Contact configuration: Normally open/normally closed contact
Number of auxiliary contacts: 2
Power: 55 W
Reset: Automatic, manual
Depth: 67.5 mm
Operating temperature range: -25 to +60 °C

The current range (A) refers to the adjustable range of the relay. To enable the tripping sensitivity, the usable current range must be below the maximum specified value. Please refer to the manufacturer's data sheet for specific product information. The electronic overload relay LR97 D is suitable for machine protection requirements where machines may be subjected to difficult starting conditions, standstill, high resistance moments/high inertia, and/or mechanical failures. It features 1 normally open and 1 normally closed contact, as well as an LED status indicator for voltage, start, constant, overload, and tripping. The tripping status is monitored for overload, rotor blockage, and phase failure. It has manual and automatic reset functions. Dimensions: H 64.5 mm x W 45 mm x D 67.5 mm.

Key specifications

input voltage
24 V
Electric current output
7 A
Output current type
AC/DC

General information

Item number
9729646
Manufacturer
Schneider Electric
Category
Relays
Manufacturer No.
LR97D07B
Release date
24.9.2018

Relay properties

input voltage
24 V
Electric current output
7 A
Output current type
AC/DC
Number of openers
1x
Number of closers
1x
Max. Switching capacity
0.06 kW

Origin

Country of origin
FranceMacedoniaSouth Korea

Sustainability

Manufacturer commitment
RE100SBTi

Scope of delivery

Scope of delivery
1 pc.

Product dimensions

Width
45 mm
Height
64.50 mm

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Relays» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 1.Metz Connect
    0 %
  • 1.Phoenix Contact
    0 %
  • 1.Schneider Electric
    0 %
  • 5.Finder
    0.1 %
  • 6.Eaton
    0.2 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • Schneider Electric
    Not enough data
  • 1.Shelly
    2 days
  • ABB
    Not enough data
  • Aqara
    Not enough data
  • Eaton
    Not enough data

Return rate

How often is a product of this brand in the «Relays» category returned?

Source: Digitec Galaxus
  • 8.Finder
    2.8 %
  • 9.Eaton
    3.1 %
  • 10.Schneider Electric
    3.3 %
  • 11.Eltako
    3.4 %
  • 12.Aqara
    3.9 %
Source: Digitec Galaxus