ABB TF96-96 Thermal overload relay 1SAZ911201R1006

Delivered between Sat, 23.8. and Wed, 10.9.

Product details

TF96 are economical electromechanical motor protection devices for currents up to 96 A. In the event of overload, they provide reliable thermal protection for the connected motors. TF96 are typically mounted on contactors AF80 to AF96, but with the help of a standalone mounting kit, the devices can also be installed separately on a DIN rail. When the motor current set on the current scale is exceeded, the relays trigger via bimetal elements, switching the status of the two auxiliary contacts 1S/1Ö. This disconnects a pre-connected contactor. The relays allow for manual or automatic reset, and they feature a test and stop function as well as a triggered indicator. The current scale of the devices is sealable. Accessories such as reset buttons and delay timers complement the range. TF96 have a tripping class of 10, are temperature compensated, sensitive to phase failure, and have ATEX certification.

Key specifications

Electric current output
96 A
Relay type
Overload relay
Item number
33787976

General information

Manufacturer
ABB
Category
Relays
Manufacturer no.
1SAZ911201R1006
Release date
17.5.2023

Relay properties

Relay type
Overload relay
Electric current output
96 A
Manufacturer Type
TF96-96 Thermal overload relay 1SAZ911201R1006

Origin

Country of origin
China

Sustainability

Manufacturer commitment
SBTi

Voluntary climate contribution

CO₂-Emission
Climate contribution

Product dimensions

Length
106.30 mm
Width
69.90 mm
Height
106.90 mm
Weight
520 g

30-day right of return
24 Months Warranty (Bring-in)

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Relays» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 1.Schneider Electric
    0 %
  • 2.Finder
    0.1 %
  • 3.ABB
    0.2 %
  • 3.Eltako
    0.2 %
  • 5.Eaton
    0.3 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • ABB
    Not enough data
  • 1.Hager
    0 days
  • 2.Shelly
    1 day
  • Aqara
    Not enough data
  • Eaton
    Not enough data

Return rate

How often is a product of this brand in the «Relays» category returned?

Source: Digitec Galaxus
  • 1.Schalk
    0.3 %
  • 2.ABB
    0.8 %
  • 3.Phoenix Contact
    1.1 %
  • 4.Schneider Electric
    1.7 %
  • 4.Shelly
    1.7 %
Source: Digitec Galaxus