ABB Contactor Relay V50/60HZ 20-60VDC

Currently out of stock
Free shipping starting at 50.–

Product details

Area: AF Range
Series: NF
Number of Poles: 4
Coil Voltage: 60 Vac
Rated Contact Current: 6 A
Rated Contact Voltage: 690 Vac
Contact Configuration: 4 Normally Open
Number of Auxiliary Contacts: 4
Connection Type: Screw Mounting
Width: 45 mm
Maximum Operating Temperature: +70 °C

IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 No. 14. Auxiliary relay. AF auxiliary relays are AC/DC operated. The AF09-AF38 auxiliary relays feature an electronic coil interface for a wide control voltage range Ucmin - Ucmax. Only four coils cover control voltages from 24 to 500 Vac or 20 to 500 Vdc. AF.Z auxiliary relays with a Z-coil allow direct control via a PLC output with 24 Vdc, 500 mA and ensure lower power consumption of the holding coil. AF.Z auxiliary relays withstand short voltage drops and interruptions (according to SEMI F47). AF auxiliary relays have integrated surge protection and do not require additional surge protection. The auxiliary relays have mechanically linked contact elements according to Annex L of IEC 609947-5-1 and are marked on the side with the symbol for mechanical linkage.

Key specifications

input voltage
20 V
Output voltage
690 V
Output current type
AC
Electric current output
6 A
Relay type
Contactor relay
Item number
10108658

General information

Manufacturer
ABB
Category
Relays
Manufacturer no.
1SBH136001R2140
Release date
13.11.2018
External links

Relay properties

Relay type
Contactor relay
input voltage
20 V
Output voltage
690 V
Electric current output
6 A
Output current type
AC
Manufacturer Type
AF Range LF Auxiliary contactor

Sustainability

Manufacturer commitment
SBTi

Voluntary climate contribution

CO₂-Emission
Climate contribution

Product dimensions

Length
80 mm

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Relays» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 1.Schneider Electric
    0 %
  • 2.Finder
    0.1 %
  • 3.ABB
    0.2 %
  • 3.Eltako
    0.2 %
  • 5.Eaton
    0.3 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • ABB
    Not enough data
  • 1.Shelly
    2 days
  • Aqara
    Not enough data
  • Eaton
    Not enough data
  • Eltako
    Not enough data

Return rate

How often is a product of this brand in the «Relays» category returned?

Source: Digitec Galaxus
  • 2.Schneider Electric
    0.7 %
  • 3.Phoenix Contact
    1.2 %
  • 4.ABB
    1.5 %
  • 5.Shelly
    1.6 %
  • 6.Hager
    2.4 %
Source: Digitec Galaxus